this is the content-page.php file Finite Element Analysis of an Amusement Park Ride

[et_pb_section bb_built=”1″ admin_label=”section”][et_pb_row admin_label=”row”][et_pb_column type=”4_4″][et_pb_text admin_label=”Header Text” background_layout=”light” text_orientation=”left” use_border_color=”off” border_color=”#ffffff” border_style=”solid”]

Finite Element Analysis of an Amusement Park Ride

[/et_pb_text][/et_pb_column][/et_pb_row][et_pb_row admin_label=”Row” make_fullwidth=”off” use_custom_width=”off” width_unit=”on” use_custom_gutter=”off” custom_padding=”0px|||” allow_player_pause=”off” parallax=”off” parallax_method=”on” make_equal=”off” parallax_1=”off” parallax_method_1=”off” parallax_2=”off” parallax_method_2=”off”][et_pb_column type=”1_3″][et_pb_image admin_label=”Image” src=”https://www.mjengineering.com/wp-content/uploads/2017/06/finite-element-analysis-1.jpg” show_in_lightbox=”off” url_new_window=”off” use_overlay=”off” animation=”off” sticky=”off” align=”center” force_fullwidth=”off” always_center_on_mobile=”on” use_border_color=”off” border_color=”#ffffff” border_style=”solid” /][/et_pb_column][et_pb_column type=”1_3″][et_pb_image admin_label=”Image” src=”https://www.mjengineering.com/wp-content/uploads/2017/06/finite-element-analysis-2.jpg” show_in_lightbox=”off” url_new_window=”off” use_overlay=”off” animation=”off” sticky=”off” align=”center” force_fullwidth=”off” always_center_on_mobile=”on” use_border_color=”off” border_color=”#ffffff” border_style=”solid” /][et_pb_button admin_label=”request a quote Button” button_url=”/request-a-quote/” url_new_window=”off” button_alignment=”center” background_layout=”dark” custom_button=”off” button_border_width=”0″ button_letter_spacing=”0″ button_use_icon=”default” button_icon_placement=”right” button_on_hover=”on” button_letter_spacing_hover=”0″ button_text=”Request a Quote” /][/et_pb_column][et_pb_column type=”1_3″][et_pb_image admin_label=”Image” src=”https://www.mjengineering.com/wp-content/uploads/2017/06/finite-element-analysis-3.jpg” show_in_lightbox=”off” url_new_window=”off” use_overlay=”off” animation=”off” sticky=”off” align=”center” force_fullwidth=”off” always_center_on_mobile=”on” use_border_color=”off” border_color=”#ffffff” border_style=”solid” /][/et_pb_column][/et_pb_row][et_pb_row admin_label=”Row”][et_pb_column type=”4_4″][et_pb_text admin_label=”Text” background_layout=”light” text_orientation=”left” use_border_color=”off” border_color=”#ffffff” border_style=”solid”]

MJ Engineering was retained by a ride manufacturer of an amusement park ride to make sure the ride met US standards for a Virginia-based amusement park. To demonstrate that the structure conformed to local, state and federal regulations, MJ Engineering performed a finite element analysis of the structure under dynamic and static loads. We also helped to establish or guide the design of a number of different control systems including speed and safety controls. To make sure the ride was installed properly, MJ Engineering provided guidance and analysis throughout the entire installation process. Using a variety of specifications (ASTM F2291, AISC 316, AISC M015, ANSI B11.TR3, ANSI B77.1, ASME B15.1, ANSI/AWS D1.1, D14.4, BS 5400-10, SAE T833, ASCE 7) we were able to see that each segment of the ride conformed to the required standards (ASTM, AISC, ANSI, ASME, AWS, BS, SAE, ASCE).

For more information about our finite element analysis of this amusement park ride contact MJ Engineering or see below for details.

[/et_pb_text][et_pb_tabs admin_label=”Tabs” use_border_color=”off” border_color=”#ffffff” border_style=”solid”] [et_pb_tab title=”Product Description” tab_font_select=”default” tab_font=”||||” tab_line_height=”2em” tab_line_height_tablet=”2em” tab_line_height_phone=”2em” body_font_select=”default” body_font=”||||” body_line_height=”2em” body_line_height_tablet=”2em” body_line_height_phone=”2em”] MJ Engineering structurally reviewed this amusement park ride for Certification within the United States. [/et_pb_tab][et_pb_tab title=”Capabilities Applied/Processes” tab_font_select=”default” tab_font=”||||” tab_line_height=”2em” tab_line_height_tablet=”2em” tab_line_height_phone=”2em” body_font_select=”default” body_font=”||||” body_line_height=”2em” body_line_height_tablet=”2em” body_line_height_phone=”2em”]

Analysis

  • Performed FEA Analysis of the Structure under dynamic & static loads.
  • Analyzed ride under wind loads & seismic loads to demonstrate the structure conformed to the Local/State/Federal Regulations

Help to establish or guide the design of the following control systems

  • Control Cycle
  • Speed Control (braking)
  • Safety Controls
  • Operator Feedback

Provide Guidance and Analysis to the Customer During Installation
Confirm The Ride Conforms to Amusement Park Standards when Installed

[/et_pb_tab][et_pb_tab title=”Process Requirements” tab_font_select=”default” tab_font=”||||” tab_line_height=”2em” tab_line_height_tablet=”2em” tab_line_height_phone=”2em” body_font_select=”default” body_font=”||||” body_line_height=”2em” body_line_height_tablet=”2em” body_line_height_phone=”2em”]

Specifications that were applied to various segments of the ride:

  • ASTM F2291
  • AISC 316
  • AISC M015
  • ANSI B11.TR3
  • ANSI B77.1
  • ASME B15.1
  • ANSI/AWS D1.1, D14.4
  • BS 5400-10
  • SAE T833
  • ASCE 7

[/et_pb_tab][et_pb_tab title=”More Info” tab_font_select=”default” tab_font=”||||” tab_line_height=”2em” tab_line_height_tablet=”2em” tab_line_height_phone=”2em” body_font_select=”default” body_font=”||||” body_line_height=”2em” body_line_height_tablet=”2em” body_line_height_phone=”2em”]

 

Industry for Use
Amusement Park

Delivery Location
Virginia

Standards Met
ASTM
AISC
ANSI
ASME
AWS
BS
SAE
ASCE

Product Name
Finite Element Analysis of Amusement Park Ride

[/et_pb_tab] [/et_pb_tabs][/et_pb_column][/et_pb_row][/et_pb_section]